A worker whose models filesystem was 100% full kept advertising
`status: healthy`, stayed a scheduling candidate, was picked to host a
70 GB video model, accepted the staging request, transferred ~17 GB and
only then failed:

  staging .../whisper-large-v3/model.fp32-00001-of-00002.safetensors:
    upload to node b7bacbf4-... failed with status 500:
    writing file: /models/longcat-video-avatar-1.5/...: no space left on device

The node was at 937G/937G/0-avail. Total elapsed before the truth
surfaced: 16 minutes, for a decision that could never have succeeded.

The worker health signal only ever proved liveness. `/readyz`
(WorkerReadiness/NATSReadiness) checks the NATS link; `status: healthy`
in the registry is driven by heartbeat recency. Node capacity carried
VRAM and RAM but no disk figure at all, and the router compared model
size against VRAM only — nothing anywhere looked at free space on the
filesystem that staging actually writes to.

Report it, then use it:

- Workers now measure the filesystem backing their MODELS directory
  (not `/` -- staged weights land in the models path, and that mount is
  very often separate) and report `total_disk`/`available_disk` on
  registration and on every heartbeat. Free disk moves faster than VRAM
  under staging traffic, so the per-heartbeat refresh matters.
- The SmartRouter drops nodes that cannot store the model before it
  picks one. The requirement comes from `modelPayloadBytes` -- the same
  local paths `stageModelFiles` uploads, already computed for the
  size-derived load budget -- plus a 5% / 1 GiB margin, rather than a
  fixed percentage of the node's disk. A percentage threshold would take
  a small-but-usable node out of rotation for models it could hold, and
  on a homogeneous cluster would strand every node at once.
- When no node fits, scheduling fails immediately with an error naming
  the requirement and each node's free space, instead of picking one and
  discovering it mid-transfer.

Two deliberate non-changes. Low disk does not mark a node `unhealthy`:
the check is per model, so a node too small for one model stays a valid
target for smaller ones. And `total_disk == 0` means "does not report
disk" (pre-upgrade worker, or a failed stat), not "full" -- such nodes
pass through untouched so a rolling upgrade never empties the candidate
pool. A genuinely full node is distinguishable: non-zero total, zero
available. Registry read failures are logged and scheduling continues
unfiltered; a database hiccup must not wedge a cluster.

Free space is surfaced on the node detail page next to VRAM, since the
incident's signature was a node that looked entirely healthy.

Signed-off-by: Ettore Di Giacinto <mudler@localai.io>
Assisted-by: Claude Code:claude-opus-4-8[1m] [Read] [Edit] [Bash]

* feat(nodes): make the disk-headroom check operator-controllable

The admission check added in the previous commit had no off switch. A
scheduler-side veto with no escape hatch is a liability: our size
estimate can be wrong (deduplicating or compressing filesystems, a
backend that fetches its own weights rather than loading the staged
copy), and an operator who hits that has no way out but a downgrade.

Add one knob with two surfaces that share a single source of truth:

- `--distributed-disk-headroom-check` / `LOCALAI_DISTRIBUTED_DISK_HEADROOM_CHECK`
  (default true), following the `--distributed-prefix-cache` pattern for
  a default-on distributed feature.
- `distributed_disk_headroom_check` in the runtime-settings registry, so
  it can be flipped without a restart from `POST /api/settings` and from
  Settings -> Distributed in the WebUI.

Both write `DistributedConfig.DiskHeadroomDisabled`, and the SmartRouter
reads that member LIVE on every scheduling decision through a closure
over the application config rather than a value snapshotted at
construction. Env/CLI sets the boot value, the runtime setting overrides
it live, last write wins, and there is exactly one member to read.
Snapshotting would have made the runtime toggle a no-op until restart.

Disabled means WARN, not SKIP. Selection goes back to ignoring free disk
-- byte for byte the pre-check behaviour -- but the check still runs, and
when it would have rejected every node it says so, naming the knob that
suppressed it. Going quiet when switched off would reproduce the exact
condition that made the original incident expensive: a cluster doing
something that could not work and saying nothing. Disabling is also
logged once at startup. Warning only on the total-rejection case keeps
it actionable rather than chatty on a heterogeneous cluster.

Also fixes a false positive in the check itself: shared-models mode
(LOCALAI_DISTRIBUTED_SHARED_MODELS) stages nothing at all -- every node
already mounts this models directory at this path -- so demanding the
full checkpoint size of free space per node would have rejected a
cluster that needs no new bytes. The check is skipped there entirely.

Signed-off-by: Ettore Di Giacinto <mudler@localai.io>
Assisted-by: Claude Code:claude-opus-4-8[1m] [Read] [Edit] [Bash]

---------

Signed-off-by: Ettore Di Giacinto <mudler@localai.io>
Co-authored-by: Ettore Di Giacinto <mudler@localai.io>
2026-07-23 00:03:21 +02:00

252 lines
8.9 KiB
Go

package worker
import (
"cmp"
"fmt"
"net"
"os"
"strconv"
"strings"
"github.com/mudler/LocalAI/pkg/system"
"github.com/mudler/LocalAI/pkg/xsysinfo"
"github.com/mudler/xlog"
)
// effectiveBasePort returns the port used as base for gRPC backend processes.
// Priority: Addr port → ServeAddr port → 50051
func (cfg *Config) effectiveBasePort() int {
for _, addr := range []string{cfg.Addr, cfg.ServeAddr} {
if addr == "" {
continue
}
_, portStr, err := net.SplitHostPort(addr)
if err != nil {
xlog.Warn("Invalid worker address; trying the next base-port source", "addr", addr, "error", err)
continue
}
port, err := strconv.Atoi(portStr)
if err != nil {
xlog.Warn("Invalid worker port; trying the next base-port source", "addr", addr, "port", portStr, "error", err)
continue
}
if port > 0 && port <= 65535 {
return port
}
xlog.Warn("Worker port is outside the valid range; trying the next base-port source", "addr", addr, "port", port)
}
return 50051
}
// effectiveMaxPort returns the last port the gRPC backend allocator may hand
// out. The range is [basePort, maxPort]; its width is the number of backend
// processes this worker can run concurrently, minus whatever the port
// quarantine is holding at the time.
//
// An unset, non-positive, or out-of-order value falls back to 65535 — the
// historical (unbounded) behaviour clamped to something bindable.
// Misconfiguring this must not shrink the range to nothing and wedge every
// backend start on the worker.
func (cfg *Config) effectiveMaxPort(basePort int) int {
if cfg.GRPCMaxPort <= 0 {
return defaultMaxPort
}
if cfg.GRPCMaxPort > defaultMaxPort {
xlog.Warn("Configured gRPC max port is above the highest TCP port; clamping",
"configured", cfg.GRPCMaxPort, "max", defaultMaxPort)
return defaultMaxPort
}
if cfg.GRPCMaxPort < basePort {
xlog.Warn("Configured gRPC max port is below the base port; ignoring it and using the full range",
"configured", cfg.GRPCMaxPort, "basePort", basePort, "max", defaultMaxPort)
return defaultMaxPort
}
return cfg.GRPCMaxPort
}
// advertiseAddr returns the address the frontend should use to reach this node.
func (cfg *Config) advertiseAddr() string {
if cfg.AdvertiseAddr != "" {
return cfg.AdvertiseAddr
}
if cfg.Addr != "" {
return cfg.Addr
}
hostname, err := os.Hostname()
if err != nil {
xlog.Warn("Failed to determine worker hostname; advertising localhost", "error", err)
}
return fmt.Sprintf("%s:%d", cmp.Or(hostname, "localhost"), cfg.effectiveBasePort())
}
// resolveHTTPAddr returns the address to bind the HTTP file transfer server to.
// Uses basePort-1 so it doesn't conflict with dynamically allocated gRPC ports
// which grow upward from basePort.
func (cfg *Config) resolveHTTPAddr() string {
if cfg.HTTPAddr != "" {
return cfg.HTTPAddr
}
return fmt.Sprintf("0.0.0.0:%d", cfg.effectiveBasePort()-1)
}
// advertiseHTTPAddr returns the HTTP address the frontend should use to reach
// this node for file transfer.
func (cfg *Config) advertiseHTTPAddr() string {
if cfg.AdvertiseHTTPAddr != "" {
return cfg.AdvertiseHTTPAddr
}
advertiseAddr := cfg.advertiseAddr()
advHost, _, err := net.SplitHostPort(advertiseAddr)
if err != nil {
xlog.Warn("Invalid worker advertise address; advertising file transfer on localhost", "addr", advertiseAddr, "error", err)
advHost = "localhost"
}
httpPort := cfg.effectiveBasePort() - 1
return net.JoinHostPort(advHost, strconv.Itoa(httpPort))
}
// registrationBody builds the JSON body for node registration.
func (cfg *Config) registrationBody() map[string]any {
nodeName := cfg.NodeName
if nodeName == "" {
hostname, err := os.Hostname()
if err != nil {
nodeName = fmt.Sprintf("node-%d", os.Getpid())
} else {
nodeName = hostname
}
}
// Detect GPU info for VRAM-aware scheduling
totalVRAM, err := xsysinfo.TotalAvailableVRAM()
if err != nil {
xlog.Debug("Failed to detect worker VRAM; registering without GPU capacity", "error", err)
}
gpuVendor, err := xsysinfo.DetectGPUVendor()
if err != nil {
xlog.Debug("Failed to detect worker GPU vendor; registering without vendor metadata", "error", err)
}
// Compute capability (e.g. "12.1" for GB10) lets the router pick per-arch
// options (e.g. larger physical batch on Blackwell). Detected on the worker
// because only the worker sees the GPU in distributed mode.
gpuComputeCap := xsysinfo.NVIDIAComputeCapability()
// Report our own meta-backend capability so the controller can list the
// backends this cluster can actually run. The controller cannot infer it
// from the GPU vendor alone: OS-dependent capabilities (metal, darwin-x86,
// nvidia-l4t) and the CUDA runtime refinements are only observable here.
capability := ""
if systemState, err := system.GetSystemState(); err != nil {
xlog.Warn("Could not detect system capability for node registration", "error", err)
} else {
capability = systemState.DetectedCapability()
}
maxReplicas := cfg.MaxReplicasPerModel
if maxReplicas < 1 {
maxReplicas = 1
}
body := map[string]any{
"name": nodeName,
"address": cfg.advertiseAddr(),
"http_address": cfg.advertiseHTTPAddr(),
"total_vram": totalVRAM,
"available_vram": totalVRAM, // initially all VRAM is available
"gpu_vendor": gpuVendor,
"gpu_compute_capability": gpuComputeCap,
"capability": capability,
"max_replicas_per_model": maxReplicas,
}
// Report free space on the filesystem that backs the MODELS directory.
// That is where staged weights land, so it is the only mount whose free
// space decides whether this node can accept a model — the scheduler uses
// it to avoid picking a node that would fail with ENOSPC mid-transfer.
if diskInfo, err := xsysinfo.GetDiskInfo(cfg.ModelsPath); err != nil {
// Omitted, not zeroed: total_disk == 0 is how the frontend recognises
// "this worker does not report disk" and keeps it in rotation.
xlog.Warn("Failed to detect worker models-path disk capacity; registering without it",
"path", cfg.ModelsPath, "error", err)
} else {
body["total_disk"] = diskInfo.Total
body["available_disk"] = diskInfo.Available
}
// Report the operator-set budget as a STRING so the server resolves and
// enforces it against the raw VRAM above. The worker never caps its own
// total_vram/available_vram, and never touches the xsysinfo process-global
// budget (that is standalone-only). Omit when unset.
if cfg.VRAMBudget != "" {
body["vram_budget"] = cfg.VRAMBudget
}
// If no GPU detected, report system RAM so the scheduler/UI has capacity info
if totalVRAM == 0 {
ramInfo, err := xsysinfo.GetSystemRAMInfo()
if err != nil {
xlog.Debug("Failed to detect worker RAM for registration", "error", err)
} else {
body["total_ram"] = ramInfo.Total
body["available_ram"] = ramInfo.Available
}
}
if cfg.RegistrationToken != "" {
body["token"] = cfg.RegistrationToken
}
// Parse and add static node labels. Always include the auto-label
// `node.replica-slots=N` so AND-selectors in ModelSchedulingConfig can
// target high-capacity nodes (e.g. {"node.replica-slots":"4"}).
labels := make(map[string]string)
if cfg.NodeLabels != "" {
for _, pair := range strings.Split(cfg.NodeLabels, ",") {
pair = strings.TrimSpace(pair)
if k, v, ok := strings.Cut(pair, "="); ok {
labels[strings.TrimSpace(k)] = strings.TrimSpace(v)
}
}
}
labels["node.replica-slots"] = strconv.Itoa(maxReplicas)
body["labels"] = labels
return body
}
// heartbeatBody returns the current VRAM/RAM stats for heartbeat payloads.
//
// When aggregate VRAM usage is unknown (no GPU, or temporary detection
// failure), we deliberately OMIT available_vram so the frontend keeps its
// last good value — overwriting with 0 makes the UI show the node as "fully
// used", while reporting total-as-available lies to the scheduler about
// free capacity.
func (cfg *Config) heartbeatBody() map[string]any {
body := map[string]any{}
aggregate := xsysinfo.GetGPUAggregateInfo()
if aggregate.TotalVRAM > 0 {
body["available_vram"] = aggregate.FreeVRAM
}
// CPU-only workers (or workers that lost GPU visibility momentarily):
// report system RAM so the scheduler still has capacity info.
if aggregate.TotalVRAM == 0 {
ramInfo, err := xsysinfo.GetSystemRAMInfo()
if err != nil {
xlog.Debug("Failed to detect worker RAM for heartbeat", "error", err)
} else {
body["available_ram"] = ramInfo.Available
}
}
// Free disk changes far faster than VRAM under staging traffic (each
// accepted model permanently consumes space), so it has to be refreshed
// every heartbeat rather than only at registration — a node that filled up
// hours after registering is precisely the case that broke.
if diskInfo, err := xsysinfo.GetDiskInfo(cfg.ModelsPath); err != nil {
xlog.Debug("Failed to detect worker models-path disk capacity for heartbeat",
"path", cfg.ModelsPath, "error", err)
} else {
body["total_disk"] = diskInfo.Total
body["available_disk"] = diskInfo.Available
}
return body
}