mirror of
https://github.com/meshtastic/firmware.git
synced 2026-10-31 12:31:02 -04:00
* LR2021: time received frames on the configured coding rate The LR2021's reported RX coding rate can pick up extra bits at a bad status read right after our own TX and keep them until a hard reset. Explicit-header frames still decode, since the rate travels in the header, but the wrong value inflates RX airtime: a latched 4/8 against a configured 4/5 times a 200-byte frame about 55% long. That feeds channel utilisation, the CSMA contention window and the reliable-router retransmit timers. computePacketTime() gains useRxHeaderInfo; LR20x0Interface passes false, so received frames are timed on the configured coding rate and CRC, and the readout task no longer reads the header info on that chip. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01GTiifXrVc4YdonmLRCeWhw * LR2021: describe the coding-rate accumulator in the comments The reported RX coding rate was described as latching after a post-TX status read. That attribution was wrong: GetLoraPacketStatus accumulates the bitwise OR of every received header's coding rate since reset, which an SX1262 injector reproduces on demand - frames at 4/5, 4/6 and 4/7 each OR their bit in, a frame at the configured rate changes nothing, and the field reaches values DS rev 2.2 Table 9-4 does not define. It is invisible on a single-coding-rate mesh, since cr | cr == cr. No behaviour change: comments only. --------- Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>