Files
python/meshtastic/telemetry_pb2.pyi
2024-04-14 12:30:14 -07:00

457 lines
14 KiB
Python

"""
@generated by mypy-protobuf. Do not edit manually!
isort:skip_file
"""
import builtins
import google.protobuf.descriptor
import google.protobuf.internal.enum_type_wrapper
import google.protobuf.message
import sys
import typing
if sys.version_info >= (3, 10):
import typing as typing_extensions
else:
import typing_extensions
DESCRIPTOR: google.protobuf.descriptor.FileDescriptor
class _TelemetrySensorType:
ValueType = typing.NewType("ValueType", builtins.int)
V: typing_extensions.TypeAlias = ValueType
class _TelemetrySensorTypeEnumTypeWrapper(google.protobuf.internal.enum_type_wrapper._EnumTypeWrapper[_TelemetrySensorType.ValueType], builtins.type):
DESCRIPTOR: google.protobuf.descriptor.EnumDescriptor
SENSOR_UNSET: _TelemetrySensorType.ValueType # 0
"""
No external telemetry sensor explicitly set
"""
BME280: _TelemetrySensorType.ValueType # 1
"""
High accuracy temperature, pressure, humidity
"""
BME680: _TelemetrySensorType.ValueType # 2
"""
High accuracy temperature, pressure, humidity, and air resistance
"""
MCP9808: _TelemetrySensorType.ValueType # 3
"""
Very high accuracy temperature
"""
INA260: _TelemetrySensorType.ValueType # 4
"""
Moderate accuracy current and voltage
"""
INA219: _TelemetrySensorType.ValueType # 5
"""
Moderate accuracy current and voltage
"""
BMP280: _TelemetrySensorType.ValueType # 6
"""
High accuracy temperature and pressure
"""
SHTC3: _TelemetrySensorType.ValueType # 7
"""
High accuracy temperature and humidity
"""
LPS22: _TelemetrySensorType.ValueType # 8
"""
High accuracy pressure
"""
QMC6310: _TelemetrySensorType.ValueType # 9
"""
3-Axis magnetic sensor
"""
QMI8658: _TelemetrySensorType.ValueType # 10
"""
6-Axis inertial measurement sensor
"""
QMC5883L: _TelemetrySensorType.ValueType # 11
"""
3-Axis magnetic sensor
"""
SHT31: _TelemetrySensorType.ValueType # 12
"""
High accuracy temperature and humidity
"""
PMSA003I: _TelemetrySensorType.ValueType # 13
"""
PM2.5 air quality sensor
"""
INA3221: _TelemetrySensorType.ValueType # 14
"""
INA3221 3 Channel Voltage / Current Sensor
"""
BMP085: _TelemetrySensorType.ValueType # 15
"""
BMP085/BMP180 High accuracy temperature and pressure (older Version of BMP280)
"""
class TelemetrySensorType(_TelemetrySensorType, metaclass=_TelemetrySensorTypeEnumTypeWrapper):
"""
Supported I2C Sensors for telemetry in Meshtastic
"""
SENSOR_UNSET: TelemetrySensorType.ValueType # 0
"""
No external telemetry sensor explicitly set
"""
BME280: TelemetrySensorType.ValueType # 1
"""
High accuracy temperature, pressure, humidity
"""
BME680: TelemetrySensorType.ValueType # 2
"""
High accuracy temperature, pressure, humidity, and air resistance
"""
MCP9808: TelemetrySensorType.ValueType # 3
"""
Very high accuracy temperature
"""
INA260: TelemetrySensorType.ValueType # 4
"""
Moderate accuracy current and voltage
"""
INA219: TelemetrySensorType.ValueType # 5
"""
Moderate accuracy current and voltage
"""
BMP280: TelemetrySensorType.ValueType # 6
"""
High accuracy temperature and pressure
"""
SHTC3: TelemetrySensorType.ValueType # 7
"""
High accuracy temperature and humidity
"""
LPS22: TelemetrySensorType.ValueType # 8
"""
High accuracy pressure
"""
QMC6310: TelemetrySensorType.ValueType # 9
"""
3-Axis magnetic sensor
"""
QMI8658: TelemetrySensorType.ValueType # 10
"""
6-Axis inertial measurement sensor
"""
QMC5883L: TelemetrySensorType.ValueType # 11
"""
3-Axis magnetic sensor
"""
SHT31: TelemetrySensorType.ValueType # 12
"""
High accuracy temperature and humidity
"""
PMSA003I: TelemetrySensorType.ValueType # 13
"""
PM2.5 air quality sensor
"""
INA3221: TelemetrySensorType.ValueType # 14
"""
INA3221 3 Channel Voltage / Current Sensor
"""
BMP085: TelemetrySensorType.ValueType # 15
"""
BMP085/BMP180 High accuracy temperature and pressure (older Version of BMP280)
"""
global___TelemetrySensorType = TelemetrySensorType
@typing_extensions.final
class DeviceMetrics(google.protobuf.message.Message):
"""
Key native device metrics such as battery level
"""
DESCRIPTOR: google.protobuf.descriptor.Descriptor
BATTERY_LEVEL_FIELD_NUMBER: builtins.int
VOLTAGE_FIELD_NUMBER: builtins.int
CHANNEL_UTILIZATION_FIELD_NUMBER: builtins.int
AIR_UTIL_TX_FIELD_NUMBER: builtins.int
UPTIME_SECONDS_FIELD_NUMBER: builtins.int
battery_level: builtins.int
"""
0-100 (>100 means powered)
"""
voltage: builtins.float
"""
Voltage measured
"""
channel_utilization: builtins.float
"""
Utilization for the current channel, including well formed TX, RX and malformed RX (aka noise).
"""
air_util_tx: builtins.float
"""
Percent of airtime for transmission used within the last hour.
"""
uptime_seconds: builtins.int
"""
How long the device has been running since the last reboot (in seconds)
"""
def __init__(
self,
*,
battery_level: builtins.int = ...,
voltage: builtins.float = ...,
channel_utilization: builtins.float = ...,
air_util_tx: builtins.float = ...,
uptime_seconds: builtins.int = ...,
) -> None: ...
def ClearField(self, field_name: typing_extensions.Literal["air_util_tx", b"air_util_tx", "battery_level", b"battery_level", "channel_utilization", b"channel_utilization", "uptime_seconds", b"uptime_seconds", "voltage", b"voltage"]) -> None: ...
global___DeviceMetrics = DeviceMetrics
@typing_extensions.final
class EnvironmentMetrics(google.protobuf.message.Message):
"""
Weather station or other environmental metrics
"""
DESCRIPTOR: google.protobuf.descriptor.Descriptor
TEMPERATURE_FIELD_NUMBER: builtins.int
RELATIVE_HUMIDITY_FIELD_NUMBER: builtins.int
BAROMETRIC_PRESSURE_FIELD_NUMBER: builtins.int
GAS_RESISTANCE_FIELD_NUMBER: builtins.int
VOLTAGE_FIELD_NUMBER: builtins.int
CURRENT_FIELD_NUMBER: builtins.int
IAQ_FIELD_NUMBER: builtins.int
temperature: builtins.float
"""
Temperature measured
"""
relative_humidity: builtins.float
"""
Relative humidity percent measured
"""
barometric_pressure: builtins.float
"""
Barometric pressure in hPA measured
"""
gas_resistance: builtins.float
"""
Gas resistance in MOhm measured
"""
voltage: builtins.float
"""
Voltage measured (To be depreciated in favor of PowerMetrics in Meshtastic 3.x)
"""
current: builtins.float
"""
Current measured (To be depreciated in favor of PowerMetrics in Meshtastic 3.x)
"""
iaq: builtins.int
"""
relative scale IAQ value as measured by Bosch BME680 . value 0-500.
Belongs to Air Quality but is not particle but VOC measurement. Other VOC values can also be put in here.
"""
def __init__(
self,
*,
temperature: builtins.float = ...,
relative_humidity: builtins.float = ...,
barometric_pressure: builtins.float = ...,
gas_resistance: builtins.float = ...,
voltage: builtins.float = ...,
current: builtins.float = ...,
iaq: builtins.int = ...,
) -> None: ...
def ClearField(self, field_name: typing_extensions.Literal["barometric_pressure", b"barometric_pressure", "current", b"current", "gas_resistance", b"gas_resistance", "iaq", b"iaq", "relative_humidity", b"relative_humidity", "temperature", b"temperature", "voltage", b"voltage"]) -> None: ...
global___EnvironmentMetrics = EnvironmentMetrics
@typing_extensions.final
class PowerMetrics(google.protobuf.message.Message):
"""
Power Metrics (voltage / current / etc)
"""
DESCRIPTOR: google.protobuf.descriptor.Descriptor
CH1_VOLTAGE_FIELD_NUMBER: builtins.int
CH1_CURRENT_FIELD_NUMBER: builtins.int
CH2_VOLTAGE_FIELD_NUMBER: builtins.int
CH2_CURRENT_FIELD_NUMBER: builtins.int
CH3_VOLTAGE_FIELD_NUMBER: builtins.int
CH3_CURRENT_FIELD_NUMBER: builtins.int
ch1_voltage: builtins.float
"""
Voltage (Ch1)
"""
ch1_current: builtins.float
"""
Current (Ch1)
"""
ch2_voltage: builtins.float
"""
Voltage (Ch2)
"""
ch2_current: builtins.float
"""
Current (Ch2)
"""
ch3_voltage: builtins.float
"""
Voltage (Ch3)
"""
ch3_current: builtins.float
"""
Current (Ch3)
"""
def __init__(
self,
*,
ch1_voltage: builtins.float = ...,
ch1_current: builtins.float = ...,
ch2_voltage: builtins.float = ...,
ch2_current: builtins.float = ...,
ch3_voltage: builtins.float = ...,
ch3_current: builtins.float = ...,
) -> None: ...
def ClearField(self, field_name: typing_extensions.Literal["ch1_current", b"ch1_current", "ch1_voltage", b"ch1_voltage", "ch2_current", b"ch2_current", "ch2_voltage", b"ch2_voltage", "ch3_current", b"ch3_current", "ch3_voltage", b"ch3_voltage"]) -> None: ...
global___PowerMetrics = PowerMetrics
@typing_extensions.final
class AirQualityMetrics(google.protobuf.message.Message):
"""
Air quality metrics
"""
DESCRIPTOR: google.protobuf.descriptor.Descriptor
PM10_STANDARD_FIELD_NUMBER: builtins.int
PM25_STANDARD_FIELD_NUMBER: builtins.int
PM100_STANDARD_FIELD_NUMBER: builtins.int
PM10_ENVIRONMENTAL_FIELD_NUMBER: builtins.int
PM25_ENVIRONMENTAL_FIELD_NUMBER: builtins.int
PM100_ENVIRONMENTAL_FIELD_NUMBER: builtins.int
PARTICLES_03UM_FIELD_NUMBER: builtins.int
PARTICLES_05UM_FIELD_NUMBER: builtins.int
PARTICLES_10UM_FIELD_NUMBER: builtins.int
PARTICLES_25UM_FIELD_NUMBER: builtins.int
PARTICLES_50UM_FIELD_NUMBER: builtins.int
PARTICLES_100UM_FIELD_NUMBER: builtins.int
pm10_standard: builtins.int
"""
Concentration Units Standard PM1.0
"""
pm25_standard: builtins.int
"""
Concentration Units Standard PM2.5
"""
pm100_standard: builtins.int
"""
Concentration Units Standard PM10.0
"""
pm10_environmental: builtins.int
"""
Concentration Units Environmental PM1.0
"""
pm25_environmental: builtins.int
"""
Concentration Units Environmental PM2.5
"""
pm100_environmental: builtins.int
"""
Concentration Units Environmental PM10.0
"""
particles_03um: builtins.int
"""
0.3um Particle Count
"""
particles_05um: builtins.int
"""
0.5um Particle Count
"""
particles_10um: builtins.int
"""
1.0um Particle Count
"""
particles_25um: builtins.int
"""
2.5um Particle Count
"""
particles_50um: builtins.int
"""
5.0um Particle Count
"""
particles_100um: builtins.int
"""
10.0um Particle Count
"""
def __init__(
self,
*,
pm10_standard: builtins.int = ...,
pm25_standard: builtins.int = ...,
pm100_standard: builtins.int = ...,
pm10_environmental: builtins.int = ...,
pm25_environmental: builtins.int = ...,
pm100_environmental: builtins.int = ...,
particles_03um: builtins.int = ...,
particles_05um: builtins.int = ...,
particles_10um: builtins.int = ...,
particles_25um: builtins.int = ...,
particles_50um: builtins.int = ...,
particles_100um: builtins.int = ...,
) -> None: ...
def ClearField(self, field_name: typing_extensions.Literal["particles_03um", b"particles_03um", "particles_05um", b"particles_05um", "particles_100um", b"particles_100um", "particles_10um", b"particles_10um", "particles_25um", b"particles_25um", "particles_50um", b"particles_50um", "pm100_environmental", b"pm100_environmental", "pm100_standard", b"pm100_standard", "pm10_environmental", b"pm10_environmental", "pm10_standard", b"pm10_standard", "pm25_environmental", b"pm25_environmental", "pm25_standard", b"pm25_standard"]) -> None: ...
global___AirQualityMetrics = AirQualityMetrics
@typing_extensions.final
class Telemetry(google.protobuf.message.Message):
"""
Types of Measurements the telemetry module is equipped to handle
"""
DESCRIPTOR: google.protobuf.descriptor.Descriptor
TIME_FIELD_NUMBER: builtins.int
DEVICE_METRICS_FIELD_NUMBER: builtins.int
ENVIRONMENT_METRICS_FIELD_NUMBER: builtins.int
AIR_QUALITY_METRICS_FIELD_NUMBER: builtins.int
POWER_METRICS_FIELD_NUMBER: builtins.int
time: builtins.int
"""
Seconds since 1970 - or 0 for unknown/unset
"""
@property
def device_metrics(self) -> global___DeviceMetrics:
"""
Key native device metrics such as battery level
"""
@property
def environment_metrics(self) -> global___EnvironmentMetrics:
"""
Weather station or other environmental metrics
"""
@property
def air_quality_metrics(self) -> global___AirQualityMetrics:
"""
Air quality metrics
"""
@property
def power_metrics(self) -> global___PowerMetrics:
"""
Power Metrics
"""
def __init__(
self,
*,
time: builtins.int = ...,
device_metrics: global___DeviceMetrics | None = ...,
environment_metrics: global___EnvironmentMetrics | None = ...,
air_quality_metrics: global___AirQualityMetrics | None = ...,
power_metrics: global___PowerMetrics | None = ...,
) -> None: ...
def HasField(self, field_name: typing_extensions.Literal["air_quality_metrics", b"air_quality_metrics", "device_metrics", b"device_metrics", "environment_metrics", b"environment_metrics", "power_metrics", b"power_metrics", "variant", b"variant"]) -> builtins.bool: ...
def ClearField(self, field_name: typing_extensions.Literal["air_quality_metrics", b"air_quality_metrics", "device_metrics", b"device_metrics", "environment_metrics", b"environment_metrics", "power_metrics", b"power_metrics", "time", b"time", "variant", b"variant"]) -> None: ...
def WhichOneof(self, oneof_group: typing_extensions.Literal["variant", b"variant"]) -> typing_extensions.Literal["device_metrics", "environment_metrics", "air_quality_metrics", "power_metrics"] | None: ...
global___Telemetry = Telemetry