From b8b6f4d856ce4115aff3d87ca033d1437fa8eacf Mon Sep 17 00:00:00 2001
From: Matthew Wall Set to the station model. For example, WMR200 or WMR200A. use_pc_time If True, use the computer time, otherwise use the station time. Default
- is False.
archive_interval
+Set the wmr200 archive interval in seconds. Default is 60 seconds.
+The wmr200 hardware records archive data at an immutable rate of 60 + seconds. This field may be set to a higher value enabling the weewx + engine to coalesce live data packets. However, when the wmr200 is not + connected to a system via USB or if the weewx software is not running, + the wmr200 console will continue to store weather data in onboard + console memory at a fixed rate of 60 seconds.
+erase_archive
+If True, erase onboard console memory archive on startup. Default is + False.
+archive_startup
+When retrieving archive data packets from the wmr200 onboard console + memory, there is no explicit indication that all the data has been + drained. This field specifies when to transition from archive mode to + live mode. This transition occurs when no archive packets are detected + within this time interval. Default is 120 seconds.
+
archive_threshold
+Occasionally when retrieving archive packets from the wmr200 onboard + memory a stale data packet will be detected. The archive packets are + presented in sequential order typically timestamped 60 seconds apart. + However, there is no guarantee the archive packets are exactly 60 + seconds apart. Should an incoming archive data packet timestamp exceed + the previous archive data packet one by the amount in this field it will + be dropped. Default is 1512000 seconds (1 week).
sensor_status
If True, emit sensor faults and failures to log. Default is True.
-erase_archive
-If True, erase station archive on startup. Default is False.
This section is for options relating to the Oregon Scientific WMR-918/968