Isaac Connor 75fff7a1b4 fix: ping camera before reboot in zmwatch and resolve host in Control::ping
zmwatch only gated the camera reboot attempt on CanReboot(), so it called
$control->open() even when the camera was unreachable - the common reason a
monitor has no image since startup - and blocked until the connection timed
out, logging an error each pass.

Add a ping check before open(). Move the host resolution into Control so callers
don't have to dig the ip out of the Path: add Control::host(), which returns the
cached host or derives it from the monitor's ControlAddress/Path via the shared
guess_credentials() (parsing only, no network i/o), and have ping() fall back to
it. ping() still accepts an explicit ip.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-16 18:30:02 -04:00
..