Isaac Connor 6dae282ef9 fix: return connection status from Grandstream control open
open() is contracted to return true or false so callers (zmcontrol.pl,
zmwatch.pl) can tell whether the camera is reachable, but it always ended
with an assignment that evaluated truthy and reported success regardless.
When the initial login probe failed it also rebuilt BASE_URL in the old
basic-auth style and returned without ever testing that connection.

Return 0 on a failed probe and 1 only after a successful exchange. Check
is_success() on the authcode response in the modern path, and actually issue
and check a request on the old-style URL in the fallback path so success
means we can talk to the camera. Log the previously unused ResCode.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>