Isaac ConnorandClaude Opus 5 8b14fba2db fix: bound the IPSpeaker http timeout instead of leaving it at LWP's default
LWP::UserAgent defaults to 180 seconds. Actions for a monitor are serialised
through one control daemon, so a speaker that has dropped off the network holds
that daemon for three minutes per attempt and every command queued behind it
waits. AMLink already sets a timeout; this did not.

Ten seconds, matching AMLink. The speaker answers in milliseconds when it is
reachable at all, so this only ever bounds the case where it is not - which is
the case right now.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UvTCzCbvGt8xKQRNCSA7o8