Isaac Connor ee29134bb3 fix: parse Grandstream control address with guess_credentials
The hand-rolled regex in open() mis-parsed a stream Path that carried no
credentials, e.g. rtsp://10.0.0.4:554/cam: the greedy [^:@]+ consumed the host
as the username, 554 as the password, and ADDRESS backtracked to the single
digit 4. The control daemon then dialled http://...@4, producing
"Can't connect to 4:80 (Connection timed out)".

Replace the regex with the shared URI-based Control.pm guess_credentials(),
which handles ControlAddress and Path, converts rtsp to http, and falls back to
the Monitor User/Pass. Create the LWP::UserAgent before parsing since
guess_credentials() sets credentials on it. The Grandstream login wire protocol
(challenge/authcode and old-style fallback) is unchanged.