mirror of
https://github.com/meshtastic/python.git
synced 2025-12-30 03:17:54 -05:00
group power options in --help. add --power-wait to support some boards
This commit is contained in:
2
.vscode/launch.json
vendored
2
.vscode/launch.json
vendored
@@ -180,7 +180,7 @@
|
||||
"request": "launch",
|
||||
"module": "meshtastic",
|
||||
"justMyCode": false,
|
||||
"args": ["--slog-out", "default", "--power-ppk2-meter", "--power-voltage", "3.3", "--port", "/dev/ttyUSB0", "--noproto", "--seriallog", "stdout"]
|
||||
"args": ["--slog-out", "default", "--power-ppk2-meter", "--power-wait", "--power-voltage", "3.3", "--noproto", "--seriallog", "stdout"]
|
||||
},
|
||||
{
|
||||
"name": "meshtastic test",
|
||||
|
||||
@@ -985,9 +985,33 @@ def export_config(interface):
|
||||
print(config)
|
||||
return config
|
||||
|
||||
def create_power_meter():
|
||||
"""Setup the power meter."""
|
||||
|
||||
args = mt_config.args
|
||||
meter = None # assume no power meter
|
||||
if args.power_riden:
|
||||
meter = RidenPowerSupply(args.power_riden)
|
||||
elif args.power_ppk2_supply or args.power_ppk2_meter:
|
||||
meter = PPK2PowerSupply()
|
||||
meter.setIsSupply(args.power_ppk2_supply)
|
||||
elif args.power_sim:
|
||||
meter = SimPowerSupply()
|
||||
|
||||
if meter and args.power_voltage:
|
||||
v = float(args.power_voltage)
|
||||
if v < 0.5 or v >5.0:
|
||||
meshtastic.util.our_exit("Voltage must be between 1.0 and 5.0")
|
||||
logging.info(f"Setting power supply to {v} volts")
|
||||
meter.v = v
|
||||
meter.powerOn()
|
||||
|
||||
if args.power_wait:
|
||||
input("Powered on, press enter to continue...")
|
||||
return meter
|
||||
|
||||
def common():
|
||||
"""Shared code for all of our command line wrappers"""
|
||||
"""Shared code for all of our command line wrappers."""
|
||||
logfile = None
|
||||
args = mt_config.args
|
||||
parser = mt_config.parser
|
||||
@@ -1004,6 +1028,8 @@ def common():
|
||||
meshtastic.util.support_info()
|
||||
meshtastic.util.our_exit("", 0)
|
||||
|
||||
meter = create_power_meter()
|
||||
|
||||
if args.ch_index is not None:
|
||||
channelIndex = int(args.ch_index)
|
||||
mt_config.channel_index = channelIndex
|
||||
@@ -1093,24 +1119,6 @@ def common():
|
||||
# We assume client is fully connected now
|
||||
onConnected(client)
|
||||
|
||||
# Setup power meters
|
||||
meter = None # assume no power meter
|
||||
if args.power_riden:
|
||||
meter = RidenPowerSupply(args.power_riden)
|
||||
elif args.power_ppk2_supply or args.power_ppk2_meter:
|
||||
meter = PPK2PowerSupply()
|
||||
meter.setIsSupply(args.power_ppk2_supply)
|
||||
elif args.power_sim:
|
||||
meter = SimPowerSupply()
|
||||
|
||||
if meter and args.power_voltage:
|
||||
v = float(args.power_voltage)
|
||||
if v < 0.5 or v >5.0:
|
||||
meshtastic.util.our_exit("Voltage must be between 1.0 and 5.0")
|
||||
logging.info(f"Setting power supply to {v} volts")
|
||||
meter.v = v
|
||||
meter.powerOn()
|
||||
|
||||
log_set = None
|
||||
if args.slog_out:
|
||||
# Setup loggers
|
||||
@@ -1533,7 +1541,9 @@ def initParser():
|
||||
action="store_true",
|
||||
)
|
||||
|
||||
power_supply_group = group.add_mutually_exclusive_group()
|
||||
power_group = parser.add_argument_group('Power Testing', 'Options for power testing/logging.')
|
||||
|
||||
power_supply_group = power_group.add_mutually_exclusive_group()
|
||||
|
||||
power_supply_group.add_argument(
|
||||
"--power-riden",
|
||||
@@ -1558,21 +1568,28 @@ def initParser():
|
||||
action="store_true",
|
||||
)
|
||||
|
||||
group.add_argument(
|
||||
power_group.add_argument(
|
||||
"--power-voltage",
|
||||
help="Set the specified voltage on the power-supply. Be VERY careful, you can burn things up.",
|
||||
)
|
||||
|
||||
group.add_argument(
|
||||
power_group.add_argument(
|
||||
"--power-stress",
|
||||
help="Perform power monitor stress testing, to capture a power consumption profile for the device (also requires --power-mon)",
|
||||
action="store_true",
|
||||
)
|
||||
|
||||
group.add_argument(
|
||||
power_group.add_argument(
|
||||
"--power-wait",
|
||||
help="Prompt the user to wait for device reset before looking for device serial ports (some boards kill power to USB serial port)",
|
||||
action="store_true",
|
||||
)
|
||||
|
||||
power_group.add_argument(
|
||||
"--slog-out",
|
||||
help="A directory to store structured logging to, or 'default' for automatically selected.",
|
||||
)
|
||||
|
||||
group.add_argument(
|
||||
"--ble-scan",
|
||||
help="Scan for Meshtastic BLE devices",
|
||||
|
||||
Reference in New Issue