Revert support for Interlogix Smoke Detector and Pet Immune SAW PIR Motion Sensor (#2287)

This reverts commit b605a3d2a7.
This commit is contained in:
Christian W. Zuckschwerdt
2023-02-11 18:08:53 +01:00
parent 17fe8254ff
commit ddb59c24ff

View File

@@ -165,7 +165,6 @@ static int interlogix_decode(r_device *decoder, bitbuffer_t *bitbuffer)
sprintf(device_type_id, "%01x", (reverse8(message[2]) >> 4));
switch ((reverse8(message[2]) >> 4)) {
case 0x2: device_type = "smoke"; break; //switch2 changes from closed to open on trigger and switch2 & switch4 change from closed to open on test
case 0xa: device_type = "contact"; break;
case 0xf: device_type = "keyfob"; break;
case 0x4: device_type = "motion"; break;
@@ -187,14 +186,6 @@ static int interlogix_decode(r_device *decoder, bitbuffer_t *bitbuffer)
f3_latch_state = ((message[3] & 0xe) == 0xc) ? "CLOSED" : "OPEN";
f4_latch_state = ((message[3] & 0xe) == 0x2) ? "CLOSED" : "OPEN";
f5_latch_state = ((message[3] & 0xe) == 0xa) ? "CLOSED" : "OPEN";
// PET Immune SAW PIR motion sensor logic.
} else if ((reverse8(message[2]) >> 4) == 0x4) {
low_battery = (message[3] & 0x10) ? 1 : 0;
f1_latch_state = ((message[3] & 0x04) | ((message[3] & 0x08) == 0x8)) ? "OPEN" : "CLOSED";
f2_latch_state = (message[3] & 0x01) ? "OPEN" : "CLOSED";
f3_latch_state = (message[4] & 0x40) ? "OPEN" : "CLOSED";
f4_latch_state = (message[4] & 0x10) ? "OPEN" : "CLOSED";
f5_latch_state = (message[4] & 0x04) ? "OPEN" : "CLOSED";
} else {
low_battery = (message[3] & 0x10) ? 1 : 0;
f1_latch_state = (message[3] & 0x04) ? "OPEN" : "CLOSED";