# AcuRite {id=acurite_notes}
|
|
|
|
According to Acurite, the wind speed updates every 18 seconds.
|
|
The wind direction updates every 30 seconds. Other sensors update
|
|
every 60 seconds.
|
|
|
|
In fact, because of the message structure and the data logging
|
|
design, these are the actual update frequencies:
|
|
|
|
<table>
|
|
<caption>AcuRite transmission periods</caption>
|
|
<tbody>
|
|
<tr class='first_row'><td>sensor</td><td>period</td></tr>
|
|
<tr><td>Wind speed</td><td>18 seconds</td></tr>
|
|
<tr><td>Outdoor temperature, outdoor humidity</td><td>36 seconds</td></tr>
|
|
<tr><td>Wind direction, rain total</td><td>36 seconds</td></tr>
|
|
<tr><td>Indoor temperature, pressure</td><td>60 seconds</td></tr>
|
|
<tr><td>Indoor humidity</td><td>12 minutes (only when in USB mode 3)</td></tr>
|
|
</tbody>
|
|
</table>
|
|
|
|
The station emits partial packets, which may confuse some online
|
|
services.
|
|
|
|
The AcuRite stations do not record wind gusts.
|
|
|
|
Some consoles have a small internal logger. Data in the logger
|
|
are erased when power is removed from the station.
|
|
|
|
The console has a sensor for inside humidity, but the values from
|
|
that sensor are available only by reading from the console logger.
|
|
Due to instability of the console firmware, the
|
|
WeeWX driver does not read the console
|
|
logger.
|
|
|
|
## USB Mode {id=acurite_usb_mode}
|
|
|
|
Some AcuRite consoles have a setting called "USB Mode" that controls
|
|
how data are saved and communicated:
|
|
|
|
<table id='usbmode' class='station_data'>
|
|
<caption>AcuRite USB mode</caption>
|
|
<tbody>
|
|
<tr>
|
|
<th>Mode</th>
|
|
<th>Show data<br/>in display</th>
|
|
<th>Store data<br/>in logger</th>
|
|
<th>Send data<br/>over USB</th>
|
|
</tr>
|
|
<tr><td>1</td><td>yes</td><td>yes</td><td></td></tr>
|
|
<tr><td>2</td><td>yes</td><td></td><td></td></tr>
|
|
<tr><td>3</td><td>yes</td><td>yes</td><td>yes</td></tr>
|
|
<tr><td>4</td><td>yes</td><td></td><td>yes</td></tr>
|
|
</tbody>
|
|
</table>
|
|
|
|
If the AcuRite console has multiple USB modes, it must be set to
|
|
USB mode 3 or 4 in order to work with the WeeWX driver.
|
|
|
|
Communication via USB is disabled in modes 1 and 2. Mode 4 is more reliable
|
|
than mode 3; mode 3 enables logging of data, mode 4 does not. When the
|
|
console is logging it frequently causes USB communication
|
|
problems.
|
|
|
|
The default mode is 2, so after a power failure one must use the
|
|
console controls to change the mode before
|
|
WeeWX can resume data collection.
|
|
|
|
The 01025, 01035, 01036, 01525, and 02032 consoles have a USB mode setting.
|
|
|
|
The 02064 and 01536 consoles do not have a mode setting; these
|
|
consoles are always in USB mode 4.
|
|
|
|
## Configuring with `weectl device` {id=acurite_configuration}
|
|
|
|
The [`weectl device`](../utilities/weectl-device.md) utility cannot be used to
|
|
configure AcuRite stations.
|
|
|
|
## Station data {id=acurite_data}
|
|
|
|
The following table shows which data are provided by the station
|
|
hardware and which are calculated by WeeWX.
|
|
|
|
<table class='station_data'>
|
|
<caption>AcuRite station data</caption>
|
|
<tbody class='code'>
|
|
<tr class="first_row">
|
|
<td style='width:200px'>Database Field</td>
|
|
<td>Observation</td>
|
|
<td>Loop</td>
|
|
<td>Archive</td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>barometer</td>
|
|
<td></td>
|
|
<td>S</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>pressure</td>
|
|
<td>pressure</td>
|
|
<td>H</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>altimeter</td>
|
|
<td></td>
|
|
<td>S</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>inTemp</td>
|
|
<td>temperature_in</td>
|
|
<td>H</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>outTemp</td>
|
|
<td>temperature_out</td>
|
|
<td>H</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>inHumidity</td>
|
|
<td>humidity_in</td>
|
|
<td></td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>outHumidity</td>
|
|
<td>humidity_out</td>
|
|
<td>H</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>windSpeed</td>
|
|
<td>wind_speed</td>
|
|
<td>H</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>windDir</td>
|
|
<td>wind_dir</td>
|
|
<td>H</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>rain</td>
|
|
<td>rain</td>
|
|
<td>D</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'></td>
|
|
<td>rain_total</td>
|
|
<td>H</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>rainRate</td>
|
|
<td></td>
|
|
<td>S</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>dewpoint</td>
|
|
<td></td>
|
|
<td>S</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>windchill</td>
|
|
<td></td>
|
|
<td>S</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>heatindex</td>
|
|
<td></td>
|
|
<td>S</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>rxCheckPercent</td>
|
|
<td>rssi</td>
|
|
<td>H</td>
|
|
<td></td>
|
|
</tr>
|
|
<tr>
|
|
<td class='first_col'>outTempBatteryStatus</td>
|
|
<td>battery</td>
|
|
<td>H</td>
|
|
<td></td>
|
|
</tr>
|
|
</tbody>
|
|
</table>
|
|
|
|
<p class='station_data_key'>
|
|
Each packet contains a subset of all possible readings. For example, one type
|
|
of packet contains <span class='code'>windSpeed</span>,
|
|
<span class='code'>windDir</span> and <span class='code'>rain</span>.
|
|
A different type of packet contains <span class='code'>windSpeed</span>,
|
|
<span class='code'>outTemp</span> and <span class='code'>outHumidity</span>.
|
|
</p>
|
|
|
|
<p class='station_data_key'>
|
|
<b>H</b> indicates data provided by <b>H</b>ardware<br/>
|
|
<b>D</b> indicates data calculated by the <b>D</b>river<br/>
|
|
<b>S</b> indicates data calculated by the StdWXCalculate <b>S</b>ervice<br/>
|
|
</p>
|
|
|