The W5100S Ethernet chip has only 4 hardware sockets. On RAK4631
Ethernet gateways with syslog and NTP enabled, all 4 sockets were
permanently consumed (NTP UDP + Syslog UDP + TCP API listener + TCP
API client), leaving none for MQTT, DHCP lease renewal, or additional
TCP connections.
- NTP: Remove permanent timeClient.begin() at startup; NTPClient::update()
auto-initializes when needed. Add timeClient.end() after each query to
release the UDP socket immediately.
- Syslog: Remove socket allocation from Syslog::enable(). Open and close
the UDP socket on-demand in _sendLog() around each message send.
- MQTT: Fix socket leak in isValidConfig() where a successful test
connection was never closed (PubSubClient destructor does not call
disconnect). Add explicit pubSub->disconnect() before returning.
Made-with: Cursor
Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
PlatformIO registry is (probably) rate limiting us. Mitigate by switching to GitHub source zips (based upon tags).
This change does not include any updates, simply swapping to a new download location.
* Fix TransmitHistory to improve epoch handling
* Enable epoch handling in unit tests
* Improve comments and test handling for epoch persistence in TransmitHistory
* Add boot-relative timestamp handling and unit tests for TransmitHistory
* loadFromDisk should handle legacy entries and clean up old v1 files after migration
* Revert "loadFromDisk should handle legacy entries and clean up old v1 files after migration"
This reverts commit eb7e5c7acf.
* Add NodeInfoModule integration for RTC quality changes and trigger immediate checks
* Update test conditions for RTC quality checks
* Fix TAG low‑voltage reboot hang after App configuration
* nRF52: Move low-VDD System OFF logic to variant hook
* Addressed review
* serialize SAADC access with shared mutex for VDD and battery reads
* raise LPCOMP wake threshold to ensure rising-edge wake
* Trunk fmt
---------
Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
We cache and dedupe our dependencies, referring to them with multiple methods/urls is just noise.
```
lewisxhe/XPowersLib@0.3.3
lewisxhe/SensorLib@0.3.4
```
This does *not* include any updates, just a cleanup.
* fix(routing): prevent licensed users from rebroadcasting packets from unlicensed or unknown users
* fix(routing): prevent licensed users from rebroadcasting packets to or from unlicensed users
---------
Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
* fix: apply all LoRa config changes live without rebooting
All LoRa radio settings (SF, BW, CR, frequency, power, preset,
sx126x_rx_boosted_gain) now apply immediately via reconfigure()
without requiring a node reboot.
- AdminModule: requiresReboot = false for all LoRa config changes;
LoRa changes were already handled by the configChanged observer
calling reconfigure() but the reboot flag was set unnecessarily
- AdminModule: validate LORA_24 region against radio hardware at
config time; reject with BAD_REQUEST if hardware lacks 2.4 GHz
capability (wideLora() returns false or no radio instance)
- SX126xInterface/LR11x0Interface: apply sx126x_rx_boosted_gain in
reconfigure(); register 0x08AC is writable in STDBY mode (SX1261/2
datasheet §9.6); retention registers written so setting survives
warm-sleep cycles; log warning on setter failure
- DebugRenderer: show BW/SF/CR on debug screen when custom modem is
active instead of the preset name
- DisplayFormatters: clarify comment on getModemPresetDisplayName
* fix: remove redundant reboot after LoRa config changes in on-device menus
Region, frequency slot, and radio preset pickers in MenuHandler all
called reloadConfig() then immediately set rebootAtMsec. reloadConfig()
already fires the configChanged observer which calls reconfigure(), so
the forced reboot was unnecessary — same rationale as the parent commit.
* fix: guard LORA_24 region selection against hardware capability in on-device menu
Without a reboot, reconfigure() now applies region changes directly.
Previously getRadio() caught the LORA_24-on-sub-GHz mismatch post-reboot
and reverted to UNSET — that safety net is gone. Add an explicit wideLora()
check in LoraRegionPicker so sub-GHz-only hardware silently ignores LORA_24
selection instead of attempting a live reconfigure with an invalid frequency.
---------
Co-authored-by: elwimen <elwimen@users.noreply.github.com>
Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
The touch-to-backlight feature was gated behind TTGO_T_ECHO_PLUS, but
the regular T-Echo has the same backlight pin (PIN_EINK_EN, P1.11).
This changes the guard to use PIN_EINK_EN only, so any device with an
e-ink backlight pin gets the feature.
Fixes#7630
Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
* Fix issue 9792, decode packet for TR test
* Fix 9792: Assure packet id decoded for TR test
* Potential fix for pull request finding
Log improvement for failure to decode packet.
Co-authored-by: Copilot Autofix powered by AI <175728472+Copilot@users.noreply.github.com>
* trunk fmt
---------
Co-authored-by: Copilot Autofix powered by AI <175728472+Copilot@users.noreply.github.com>
Co-authored-by: Tom Fifield <tom@tomfifield.net>
* fix: MQTT settings silently fail to persist when broker is unreachable
isValidConfig() was testing broker connectivity via connectPubSub() as
part of config validation. When the broker was unreachable (network not
ready, DNS failure, server down), the function returned false, causing
AdminModule to skip saving settings entirely — silently.
This removes the connectivity test from isValidConfig(), which now only
validates configuration correctness (TLS support, default server port).
Connectivity is handled by the MQTT module's existing reconnect loop.
Fixes#9107
* Add client warning notification when MQTT broker is unreachable
Per maintainer feedback: instead of silently saving when the broker
can't be reached, send a WARNING notification to the client saying
"MQTT settings saved, but could not reach the MQTT server."
Settings still always persist regardless of connectivity — the core
fix from the previous commit is preserved. The notification is purely
advisory so users know to double-check their server address and
credentials if the connection test fails.
When the network is not available at all, the connectivity check is
skipped entirely with a log message.
* Address Copilot review feedback
- Fix warning message wording: "Settings will be saved" instead of
"Settings saved" (notification fires before AdminModule persists)
- Add null check on clientNotificationPool.allocZeroed() to prevent
crash if pool is exhausted (matches AdminModule::sendWarning pattern)
- Fix test comments to accurately describe conditional connectivity
check behavior and IS_RUNNING_TESTS compile-out
* Remove connectivity check from isValidConfig entirely
Reverts the advisory connectivity check added in the previous commit.
While the intent was to warn users about unreachable brokers,
connectPubSub() mutates the isConnected state of the running MQTT
module and performs synchronous network operations that can block
the config-save path.
The cleanest approach: isValidConfig() validates config correctness
only (TLS support, default server port). The MQTT reconnect loop
handles connectivity after settings are persisted and the device
reboots. If the broker is unreachable, the user will see it in the
MQTT connection status — no special notification needed.
This returns to the simpler design from the first commit, which was
tested on hardware and confirmed working.
* Use lightweight TCP check instead of connectPubSub for validation
Per maintainer feedback: users need connectivity feedback, but
connectPubSub() mutates the module's isConnected state.
This uses a standalone MQTTClient TCP connection test that:
- Checks if the server IP/port is reachable
- Sends a WARNING notification if unreachable
- Does NOT establish an MQTT session or mutate any module state
- Does NOT block saving — isValidConfig always returns true
The TCP test client is created locally, used, and destroyed within
the function scope. No side effects on the running MQTT module.
---------
Co-authored-by: Ben Meadors <benmmeadors@gmail.com>
The touch-to-backlight feature was gated behind TTGO_T_ECHO_PLUS, but
the regular T-Echo has the same backlight pin (PIN_EINK_EN, P1.11).
This changes the guard to use PIN_EINK_EN only, so any device with an
e-ink backlight pin gets the feature.
Fixes#7630
Co-authored-by: Ben Meadors <benmmeadors@gmail.com>